MC-3000 series coating thickness gauge
MC-3000 series coating thickness gauge containsMC-3000B (embedded probe), MC-3000S (detachable probe) and MC-3001 three typesof coating thickness gauge, MC-3000B, MC- 3000S with a single probe; MC-3001models can be configured at the same time a variety of different probes,according to the probe type can measure a variety of metal above the coating The instrument assimilate into a professionalindustrial design concept,So that the instrument operation more humane.2.4 inches TFTcolor screen;Bluetooth 2.0wireless communication interface;KODIN company developour own PLL technique to make measuring work more stable;Flip display、Chinese andEnglish switch、multi measuringmode ,These features can make gauge moresuited to the job requirements of the industrial field and provide customerswith more convenience. Its performance has reached the contemporaryinternational advanced level of similar gauge.
Main performance of 3000B/S/3001
■ With three calibration methods, basic calibration method capable of error correction system
■ Can store more than 10,000 measurement data
■ Can delete a storage group suspicious data, you can also delete all stored data
■ Overrun value can automatically alarm
■ Languages: Chinese, English
■ Units: metric, imperial
■ Bluetooth 2.0, with the computer and printer for wireless communication
■ Low power voltage indicator
■ Manual shutdown and automatic shutdown mode
■ V-groove structure to facilitate measuring coating the outer surface of the pipe in various sizes
■ Dedicated large flat probe structure makes the instrument more stable
Model | Measurement range | Resolution | Accuracy | Probe |
MC-3000B | 0-9000um (According to different types of probes measuring different thickness) | 0~100μm:0 .1μm; 100~999μm: 1μm; 1mm~9mm: 0.01mm | ±(1~3% )H±1 Or H±2μm (H is the measured thickness of the coating layer) | built-in probe |
MC-3000S | Fixed line probe | |||
MC-3001 | Can choose different probe collocation |
Probe model | F 0.5 | F 1.2 | F 3 | F 5 | F 9 | N 1.2 |
Measuring principle | Magnetic induction | Eddy current | ||||
Measuring range | 0-0.5mm | 0-1.25mm | 0-3mm | 0-5mm | 0-9mm | 0-1.25mm |
Measuring accuracy | ±(1~3% )H±1 or H±2μm (H is the measured thickness of the coating layer) | |||||
Display accuracy | 0-100μm:0.1μm; 100-999μm:1μm ; 1mm-1mm:0.01mm | |||||
Minimum plane diameter | 6mm | 9mm | 12mm | 20mm | 20mm | 9mm |
Minimum curvature radius (concave) | 5mm | 6mm | 7.5mm | 10mm | 10mm | 6mm |
Minimum curvature radius (convex) | 1.5mm | 1.5mm | 2mm | 5mm | 5mm | 1.5mm |