All Stainless Steel Gas Density Monitor
Model: SF6-DS
Features
■ OEM service
■ Strict overpressure and fatigue test
■ High frequency vibration - to eliminate residual stress in Bourdon tube
■ Specially design for destiny control
■ Gold plating contact - better conductivity and chemical stability
Main Specifications
▼Size
4”
▼Window
Safety glass
▼Process connection
Material: SS 316
Welding / With O-ring sealed
Size: 1/4”,3/8”,1/2”
Type: BSPT, NPT, PF
▼Pressure range
-1 to 6 …9 bar
▼Applicable fluid
Liquid and gas that compatible with SS 316
▼Ambient temperature
-40°C to +60°C
▼Fluid temperature
+100°C
▼Temperature error
Standard: 20℃
Every ±8℃
max. error: ±0.5% F.S
▼Protection level
IP 65
Other Specifications
▼Ring
Stainless steel
Concealed wiring
Inside bayonet
Adjust contact position by rotary button
▼Housing
SS 304
Leak rate: ≤1x10-5 (mbar/s)
▼Pointer
Aluminum with black enamel
▼Dial face
Red and black scale
▼Measuring elements
Bourdon tube
Material: SS 316
▼Movement
Stainless steel
▼Accuracy
1.5% (-30~ +60°C)
2.5% (-40~ +70°C)
▼Operating pressure
Stabilization: 3/4* full scale
Fluctuation: 3/4* full scale
Impulse: 1* full scale
▼Contact material
Gold plating
▼Contact number
Up to four sets
At least one set
▼Electrical connection
Terminal box
▼Maximum voltage
380 VAC & 220 VDC
▼Maximum load
30W or 50VA
▼Current interrupt
1.0A (Max)
▼Initial current
1.0A (Max)
▼Permanent current
0.6A (Max)
▼High pressure test
2kV, 50Hz, 1s or higher
▼Sealing ability
Leak rate: ≤1x10-5 (mbar/s)
▼Impact resistance
300m/s2
For more details, please visit official website:https://www.re-atlantis.com/